CMG3-53B-AIR System

Product Description
● Provide barrier/buffer fluid to mechanical seal, promote fluid film formation between seal faces of the  seal. ● Remove heat from the end face and improve the seal working environment. ● Monitor the seal operation status and timely alarm. ● The heat exchanger is air-cooled type and not recommended for indoor installation. ● Vessels are designed and manufactured in accordance with GB/T150 or ASME BPVC.VIII.
Design Parameters
● Pressure:≤4.0MPaG ● Temperature:-20~120℃ Customized design for particular applications.
Piping Plans
●API682 Plan53B
Configuration and Material

Parts

Material

Piping

304/316L/2205

Fin

Aluminum/304/316L

Accumulator

CS/304/316L

Performance

Interface

Connection Size

Shaft Diameter≤60mm

Shaft Diameter60mm

Barrier Inlet BI

DN15

DN20

Barrier Outlet BO

DN15

DN20

Drain D

DN15

DN15

Vent V

DN15

DN15

Spare Supplement S

NPT1/2

NPT1/2

Accumulator Charging N

M4×1.5

M4×1.5