CMGR、CMGR1 Heat Exchanger

Product Description
● Cooling or insulating of the flushing fluid. ● Spiral design of heat exchange tube, enhance heat exchange efficiency. ● Double layer layout of heat exchange tubes, featuring a more compact structure. ● Two-path construction makes flow resistance decrease in tube side. ● Detachable shell for easy cleaning scale. ● Vessels are designed and manufactured in accordance with GB/T150 or ASME BPVC.VIII.
Design Parameters
● Pressure: Tube Side ≤6.3MPaG Shell Side ≤0.8MPaG ● Temperature: Tube Side -20~450℃ Shell Side 0~99℃ Customized design for particular applications.
Piping Plans
● API682 Plan21,22,23,41
Configuration and Material

Item

Parts

Material

Tube Side

 (Flushing Fluid)

Tube

304/316L/2205

Piping

304/316L/2205

Shell Side 

(Cooling Water)

Shell

304/316L/CS

Piping

304/316L/2205/CS

Performance

Model

Parameters

CMGR-03

CMGR1-06

CMGR-07

CMGR-09

CMGR-12

Heat Exchange Area

0.3㎡

0.6㎡

0.7㎡

0.9㎡

1.2㎡

Flush Inlet FI

DN15

DN15

DN15

DN15

DN15

Flush Outlet FO

DN15

DN15

DN15

DN15

DN15

Cooling Water Inlet CI

DN20

DN25

DN25

DN25

DN25

Cooling Water Outlet CO

DN20

DN25

DN25

DN25

DN25

Vent V

NPT3/8

NPT3/8

NPT3/8

NPT3/8

NPT3/8

Drain D

NPT1/2

NPT1/2

NPT1/2

NPT1/2

NPT1/2